AnythingOnline
🧪
Boiler Acid Dew Point & Cold End Corrosion Calculator engineering
100% Free • No Sign-Up

Boiler Acid Dew Point & Cold End Corrosion Calculator

Determine sulfuric acid vapor condensation temperature ($T_{adp}$), flue gas $SO_3$ concentration, and air preheater minimum metal temperature margin.

Fuel Chemistry & Flue Gas

Typically 1.5% to 4.0%
Average of air in and gas out

Acid Dew Point & Corrosion Prevention

Sulfuric Acid Dew Point (T_adp):
Flue Gas SO3 Concentration:
Min Safe Cold-End Metal Temp:
Current Temperature Margin:
Cold End Corrosion Risk:
Water Vapor Dew Point:

Recommended Tools & Equipment

Tested hardware and components for high reliability

100% Free Tool Zero Sign-Up

Verhoff-Banchero Acid Dew Point Chemistry

During fossil fuel combustion, sulfur burns to sulfur dioxide ($SO_2$). In the high-temperature furnace and across vanadium/iron catalyst deposits, a small fraction ($1\%$ to $4\%$) oxidizes into sulfur trioxide ($SO_3$). Below $300^\circ\text{C}$, $SO_3$ instantly hydrates with flue gas moisture to form sulfuric acid vapor ($H_2SO_4$).

Cold-End Air Preheater Corrosion

Even a tiny concentration of $SO_3$ (just $15\text{ to } 30\text{ ppm}$) raises the dew point of the flue gas from $50^\circ\text{C}$ (pure water dew point) up to $135^\circ\text{C} - 150^\circ\text{C}$ ($275^\circ\text{F} - 300^\circ\text{F}$). If rotary air heater baskets, baghouse filters, or ID fan casings drop below this temperature, concentrated ($70 - 85\%$) sulfuric acid condenses, corroding carbon steel plates within weeks.

Frequently Asked Questions