SCR DeNOx Ammonia Injection & Slip Calculator engineering
100% Free • No Sign-Up

SCR DeNOx Ammonia Injection & Slip Calculator

Size anhydrous or aqueous ammonia reagent consumption, NH3/NOx molar stoichiometry, and monitor ammonium bisulfate (ABS) air preheater fouling boundaries.

Flue Gas & NOx Conditions

Optimal SCR window: 620°F - 750°F

DeNOx Reagent & Slip Results

Reagent Injection Rate:
Pure NH3 Consumption:
Outlet Stack NOx:
Mass NOx Removed:
NH3 / NOx Molar Ratio:
Ammonium Bisulfate (ABS) Risk:

Recommended Tools & Equipment

Tested hardware and components for high reliability

100% Free Tool Zero Sign-Up

Selective Catalytic Reduction (SCR) Principles

Selective Catalytic Reduction (SCR) converts toxic nitrogen oxides ($NO_x = NO + NO_2$) into harmless atmospheric nitrogen ($N_2$) and water vapor by reacting with injected ammonia over a titanium-vanadium ($V_2O_5 / TiO_2$) honeycomb or plate catalyst.

Ammonium Bisulfate (ABS) Danger

Any unreacted ammonia (known as ammonia slip) that passes through the catalyst reacts with flue gas sulfur trioxide ($SO_3$) at temperatures below $400^circ ext{F} - 450^circ ext{F}$ to form sticky, corrosive liquid ammonium bisulfate ($NH_4HSO_4$), which glues fly ash to downstream rotary air preheater baskets.